Fall Harvest Sale – Ends 11/08/24! Call or chat today! Large Project? Request a Quote.

800 ft² METALLIC EPOXY FLOORING - "Simple Kit"

Simple kits make applying our Metallic Epoxy a simple, and straight forward process. Get everything you need to complete your project and get the look you want by choosing one of our popular predesigned floor options. Then add it to your cart. I ...
  • $1,965.86

Simple kits make applying our Metallic Epoxy a simple, and straight forward process. Get everything you need to complete your project and get the look you want by choosing one of our popular predesigned floor options. Then add it to your cart. It's that simple. This kit covers 800 ft² Floor - @ 70 Sq Ft per gallon @ 30 to 24 mils thick! Includes 3 gallons of our superior waterborne primer HD-WB / 267 ft² gallon @ 6 mils.  (4) 3 Gallon Kits of CLEAR100, (4) 12oz Metallic Pigments, and 4 gallons of WB ONE - Acrylic Urethane Topcoat! During our sale we've marked this kit down so that WB ONE is FREE! Sorry, if you recieved a discount code for free shipping, it should not work on this kit. If our website accepts the FREE shipping coupon, we will require additional payment for shipping once we prepare an accurate shipping quote. 


This kit is marked down from $2,265.94 to $1,965.86 - Thats $306.04 in instant savings! 2 Coats of WB ONE Topcoat included FREE!


Spartan Epoxies' Simple Kits are crafted to make the process of installing a metallic epoxy floor as straightforward as possible, without compromising on quality or finish. From the robust base provided by our HDWB primer to the lustrous depth of the CLEAR100 metallic epoxy, every aspect of our kit is designed with the user in mind. Whether you're a DIY enthusiast or a professional, our kits provide everything you need for a successful, stunning floor transformation.


Coverage for Metallic Epoxy Only (CLEAR100 + Metallic Pigment):

30 mils / 50 ft² per gallon / CRAZY THICK

26 mils / 60 ft²  per gallon / INSANELY THICK

24mils  / 70 ft² per gallon /  SUPER THICK - This Kit will cover 840 ft²

21mils  / 80 ft² per gallon / THICK

18mils / 90 ft² per gallon / COMPARES TO OUR COMPETITION


What's Included:

• 3 Gallons of HDWB Epoxy Primer / 2 Gallon Kit + 1 Gallon Kit @ 6 mils - covers up to 801 ft². 

• (4) 3 Gallon Kits of CLEAR100. Metallic Epoxy System. CLEAR100 + Metallic Pigment. Covers 600 ft² @ 30 mils CRAZY THICK, and 24 mils SUPER THICK - covers 840 ft²

• (4) 12oz Containers of our Rich, 3D - Metallic Pigment Powder. Depending on the the design you choose will depend on the pigments that ship with your kit.

• WB ONE Acrylic Urethane Topcoat (2 Coats): To seal and protect your metallic epoxy floor, the kit includes two coats of WB ONE Acrylic Urethane topcoat. This unique formulation provides a smooth, high-gloss finish without the orange peel texture often seen with other urethanes, enhancing the floor's aesthetic and durability. Coverage rate for WB ONE: Coat 1: 400 ft² / gallon, Coat 2: 534 ft² / gallon. Purchase more if you would like to add a third coat of WB ONE here


Want to customize your Simple Kit? Here's how you could add highlight colors to your kit. 

Click here to add additional ribbon kits to your project. Adding a 3/4 gallon ribbon kit to your floor will enable you to customize your Simple Kit. If you want to completely customize your kit, head over to our standard kits which enables you to customize each 12oz Metallic PIgment for each 3 gallon kit of CLEAR100. Click here to go there now.

Highlight colors go far. You can figure for 1000 sq ft, you will need 1 quart per color, per 500 ft² or more, depending on your installation technique. We generally like to see what we call a slick coat of the main color. Others may call this the "base coat" or a "flood coat". Essentially it's your main color. You need enough epoxy assigned to the slick coat to cover your full square footage. For example, if you have 1000 sq ft, you will need 15 gallon of epoxy assigned to your slick coat. However if you decide to pour random ribbons of color instead of doing a slick coat you can certainly apply in this way. You get less control, however your floor have more of a swirling or marble look.  If you need our advice for your project, call us. We'll walk you thru the process.

Preparation, Mixing and Installation Instructions for Primer / Base - HD PRO High Solids System. This kit includes HD PRO, our superior and most versatile base system. 


1) PRODUCT STORAGE: Store product in an area so as to bring the material to normal room temperature before using. Continuous storage should be between 60 and 90 degrees F. Low temperatures or great temperature fluctuations may cause crystallization.


2) SURFACE PREPARATION: The most suitable surface preparation would be a fine brush blast (shot blast) to remove all laitance and provide a suitable profile. All dirt, foreign contaminants, oil, and laitance must be removed to assure a trouble free bond to the substrate. A test should be made to determine that the substrate (Concrete, Laminate, Tile, Formica, MDF, etc) is dry; this can be done by placing a 4’X4’ plastic sheet on the substrate and taping down the edges. If after 24 hours, the substrate is still dry below the plastic sheet, then the substrate is dry enough to start coating. The plastic sheet testing is also a good method to determine if any hydrostatic pressure problems exist that may later cause dis-bonding.


3) PRODUCT MIXING: This product has a mix ratio of 12# part A to 3.85# part B for standard colors. Standard packages are in pre-measured kits and should be mixed as supplied in the kit. We highly recommend that the kits not be broken down unless suitable weighing equipment is available. After the two parts are combined, mix well with slow speed mixing equipment such as a jiffy mixer until the material is thoroughly mixed and streak free. After mixing, transfer the mixed material to another pail (the transfer pail) and again remix. The material in the transfer pail is now ready to be applied on the primed substrate. Improper mixing may result in product failure.


4) PRIMING: This product is only intended as a high solids primer suitable for most substrates. However, if the surface is very porous, then a lower solids primer might be more suitable to reduce the possibility of air release problems occurring. Contact your Spartan Epoxies sales rep for more information.


5) PRODUCT APPLICATION: The mixed material can be applied by brush or roller. However, the material can also be applied by a suitable serrated squeegee and then back rolled as long as the appropriate thickness recommendations are maintained. Maintain temperatures and relative humidity within the recommended ranges during the application and curing process. If concrete conditions or over aggressive mixing causes air entrapment, then an air release roller tool should be used prior to the coating tacking o to remove the air entrapped in the coating. Thinner applications will not level as well as higher build applications.


6) RECOAT OR TOPCOATING: Although a topcoat is recommended, it is optional. Many topcoats are suitable for placement over this coating including both urethanes and epoxies. When top coating this product, you must first be sure that the coating has tacked o before top coating can commence. Before top coating, check the coating to verify no epoxy blushes were developed (a whitish, greasy film or de-glossing). If a blush is present, it must be removed prior to top coating. A standard type detergent cleaner can be used to remove any blush. Many epoxy coatings and urethanes are compatible for use as a topcoat for this product as well as multiple coats of this product as an intermediate build coat.


7) CLEANUP: Xylol is the most effective, but if you wish not to use xylol, you can use acetone or alcohol. Xylol is the best and most recommended. Remember to protect your skin and eyes.


8) CLEANING: Caution! Some cleaners may affect the color of the epoxy installed. Test each cleaner in a small area, utilizing your cleaning technique. If no ill effects are noted, you can continue to clean with the product and process tested.


9) RESTRICTIONS: Restrict the use of the surface to light traffic and non-harsh chemicals until the coating is fully cured (see technical data under full cure). It is best to let the floor remain dry for the full cure cycle. Dependent on actual complete system application, the surface may be slippery, especially when wet or contaminated; keep the surface clean and dry.

Preparation, Mixing and Installation Instructions for SPE-META-UV / 100% CLEAR EPOXY BINDER System. 


1.) PRODUCT STORAGE: Store product in an area so as to bring the material to normal room temperature before using. Continuous storage should be between 60 and 90 degrees F. Low temperatures or temperature fluctuations may cause crystallization.


2.) SURFACE PREPARATION: The most suitable surface preparation would be a fine brush blast (shot blast) to remove all laitance and provide a suitable profile. All dirt, foreign contaminants, oil, and laitance must be removed to assure a trouble free bond to the substrate. A test should be made to determine that the substrate (Concrete, Laminate, Tile, Formica, MDF, etc) is dry; this can be done by placing a 4’X4’ plastic sheet on the substrate and taping down the edges. If after 24 hours, the substrate is still dry below the plastic sheet, then the substrate is dry enough to start coating. The plastic sheet testing is also a good method to determine if any hydrostatic pressure problems exist that may later cause disbanding.


3.) PRODUCT MIXING: When mixing metallics take part B, open and pour into bucket, next open Metallic container and slowly pour into part B while mixing thoroughly. Make sure metallics achieve wetness. Once all metallics are mixed thoroughly add Part A and again mix thoroughly. To prevent air from being introduced into the epoxy, DO NOT lift mixing blade out of epoxy while mixing. This product has a mix ratio of 9.0# part A to 4.15# part B. Standard packages are in pre-measured kits and should be mixed as supplied in the kit. We highly recommend that the kits not be broken down unless suitable weighing equipment is available. After the two parts are combined, mix well with slow speed mixing equipment such as a jiffy mixer until the material is thoroughly mixed and streak free. After mixing, transfer the mixed material to another pail (the transfer pail) and again remix. The material in the transfer pail is now ready to be applied on the primed substrate. Improper mixing may result in product failure.


4.) PRIMING: A suitable primer should be used before applying this product. See the front side of this technical data for primer information. If a primer is not used, more porous substrates may cause outgassing and possible surface defects.


5.) PRODUCT APPLICATION: The mixed material can be applied by brush or roller. However, the material can also be applied by a suitable serrated squeegee and then back rolled as long as the appropriate thickness recommendations are maintained. Maintain temperatures and relative humidity within the recommended ranges during the application and curing process. If concrete conditions or over aggressive mixing causes air entrapment, then an air release roller tool should be used prior to the coating tacking off to remove the air entrapped in the coating. This product can be used with various colored sand in a broadcast system or other suitable aggregate can be used in conjunction with this product to achieve a variety of color and application patterns. When using as a broadcast binder, always evaluate performance parameters with a test area which is dependent on aggregate size and thickness, prior to application. Contact your representative for details as necessary.


6. RECOAT OR TOPCOATING: If you opt to recoat or topcoat this product, you must first be sure that the coating has tacked o before recoating. Always remember that colder temperatures will require more cure time for the product before recoating or top coating can commence. Before recoating or top coating, check the coating to ensure no epoxy blushes were developed (a whitish, greasy film or de-glossing). If a blush is present, it must be removed prior to top coating or recoating. Many epoxy coatings and urethanes are compatible for use as a topcoat for this product as well as multiple coats of this product.


7) CLEANUP: Use xylol.


8) CLEANING: Caution! Some cleaners may affect the color. Test each cleaner in a small area. If no ill effects are noted, you can continue to clean with the product and process tested.


9) RESTRICTIONS: Restrict the use of the epoxy to light traffic/use, and non-harsh chemicals until the coating is fully cured (see technical data under full cure). It is best to let the floor remain dry for the full cure cycle. Dependent on actual complete system application, the surface may be slippery, especially when wet or contaminated; keep the surface clean and dry.

  • 0%
  • 0%
  • 0%
  • 0%
  • 0%

Reviews Over 800 ft² METALLIC EPOXY FLOORING - "Simple Kit"

Total Reviews (0)
click here write review to add review for this product.